Loadcell Manufacturing t/a ROUTE Calibration Weigh Bridges - Loadcell Manufacturing t/a ROUTE Calibration
RDSB SPECIFICATION
Equivalent to: PA6164
Route calibration ULP loadcell
PERFORMANCE
Accuracy Class
0.03 C3
Units
Rated Capacities
2.5, 5, 10, 15, 20, 25, 30, 50, 70, 100T
T
Rated Output
3mV/V ± 0.25%
mV/V
Non-linearity
0.03%
F.S
Hysteresis
0.03%
F.S
Non-repeatability
0.02%
F.S
Creep at rated output
0.03%
% of applied load
Temperature effect span
15 PPM
% of applied load/C
Temperature effect zero
26 PPM
% of rater output/C
Compensation temperature range
-10 ~ 40
Degrees C
Operating temperature range
-40 ~ 65
Degrees C
Zero balance
± 1%
F.S
Input impedance
770 ± 15
Ohms
Output impedance
700 ± 3
Ohms
Safe Overload
150%
F.S
Ultimate overload
300%
F.S
Recommended excitation
10
Volts DC
Maximum excitation
15
Volts DC
Insulation Resistance
>5000
Megaohms
Construction material
Alloy tool steel
Environmental protection
IP67
Cable
6 meter 4-core screened nitrile
DIMENSIONAL SPECIFICATION
Capacity
A
B
C
D
L
H
G
R
2.5 T - 5 T
206 133 37 43 174 28 16 12
10 T
206 133 37 43 174 28 16 12
15 T - 30 T
260 165 69 76 215 60 26 25
50 T
285 190 82 88 241 63 26 38
70 T
285 190 92 99 241 71 26 38
100 T
408 254 131 136 330 116 39 50
utytf
Wiring Diagram
Wiring diagram for ULP type loadcell