Accuracy Class |
0.1% |
0.05% |
0.03% |
Units |
---|---|---|---|---|
Rated Capacities |
1, 2, 5, 10, 20, 30, 50, 75, 100, 200 and 300 |
Tonne |
||
Rated Output |
2.0 ± 0.1% |
mV/V |
||
Creep at rated output |
0.1 |
0.05 |
0.03 |
% of applied load |
Temperature effect on output |
0.007 |
0.004 |
0.003 |
% of applied load/C |
Temperature effect on zero |
0.015 |
0.007 |
0.003 |
% of rated output/C |
Safe Overload |
200 |
% of rated Capacity |
||
Ultimate overload |
300 |
% of rated Capacity | ||
Recommended excitation |
10 |
Volts DC |
||
Maximum excitation |
15 |
Volts DC |
||
Input impedance |
350 ± 5 |
Ohms |
||
Output impedance |
350 ± 5 |
Ohms |
||
Insulation Resistance |
>11 |
Gigaohms |
||
Construction material |
Tool Steel, Electroless nickel plated |
|||
Environmental protection |
IP68 (Hermetically sealed) |
|||
Cable |
5 meter 4-core screened nitrile |
Capacity |
A1 |
A2 |
A3 |
B |
C |
D |
E |
F |
G |
H |
---|---|---|---|---|---|---|---|---|---|---|
1T/2T |
70 |
35 |
73 |
105 |
27 |
30 |
25 |
50 |
M14x2 |
M6x1 |
5T |
80 |
40 |
83 |
120 |
41 |
30 |
25 |
50 |
M20x1.5 |
M8x1.25 |
10T/20T |
90 |
45 |
95 |
155 |
59 |
30 |
25 |
50 |
M32x2 |
M10x1.5 |
30T |
100 |
50 |
107 |
180 |
70 |
30 |
25 |
50 |
M40x3 |
M12x1,75 |
50T/75T |
120 |
60 |
124 |
200 |
80 |
30 |
25 |
50 |
M45x3 |
M14x2 |
100T |
180 |
90 |
-- |
278 |
115 |
30 |
25 |
50 |
-- |
M16x2 |
200T |
180 |
-- |
-- |
350 |
145 |
30 |
25 |
50 |
-- |
M16x2 |