RBB SPECIFICATION
Equivalent to: PA6142, BM11, BELLOW LOADCELL
PERFORMANCE SPECIFICATION
Accuracy Class
0.03
Units
Rated Capacities
10, 20, 30, 50, 100 and 200
kg
Rated Output
2.0 ± 0.1%
mV/V
Creep at rated output
0.03
% of F.S.
Temperature effect on output
15
PPM/C of applied load
Temperature effect on zero
26
PPM/C of applied load
Safe Overload
150
% of rated Capacity
Ultimate overload
300
% of rated Capacity
Recommended excitation
10
Volts DC
Maximum excitation
15
Volts DC
Input impedance
385 ± 15
Ohms
Output impedance
350 ±3
Ohms
Insulation Resistance
>5000
Megaohms
Construction material
Alloy tool steel
Environmental protection
IP68 (Hermetically sealed)
Cable
6 meter 4-core screened nitrile
DIMENSIONALSPECIFICATION
ULP Loadcell dimensional sketch
Wiring Diagram
Wiring diagram for single point type loadcellRoute calibration ULP loadcell
RULP Specification sheet - Loadcell Manufacturing t/a ROUTE Calibration